WZC-130B,WZP-220B,WZP-221B,WZP-230B,WZP-231B,WZP2-220B,WZP2-221B,WZP2-230B,WZP2-231B,WZP-220AB,WZP2-220AB。WZC-220B,WZC-230B,WZC-220AB,WZP-320B,WZP-321B,WZP-330B,WZP-331B,WZP2-320B,WZP2-321B,WZP2-330B,WZP2-330B,WZC-320B,WZC-320B,WZP-420B,WZP-421B,WZP-430B,WZP-431B,WZP2-420B,WZP2-421B,WZP2-430B,WZP2-431B,WZP-42AB,WZP2-42AB,WZC-420B,WZC-430B,WZP-420B,WZP-421B,WZP-430B,WZP-430B,WZP-431B,WZP2-420B,WZP2-421B,WZP2-430B,WZP2-431B,WZP-42AB,WZP2-42AB,WZP-420B,WZC-430B,WZP-621B,WZP-621AB,WZP-631B,WZP2 -621B,WZP2 -621B,WZP2 -631B,WZP-621B,WZP-631B,WZP-621B,WZP2 -631B,WZP-621AB,WZP2-621AB,WZP-002,WZP-003,WZP-003A,WZCM-201,WZPM-201,WZPM-201,WZP-270S,WZP-26S,WZP-236SB,
量程规格
名 称 分度号 测温范围 ℃ 精度等级 允 差Δt
镍铬-镍硅热电偶 K 0~800 2 ±2.5℃或 ±0.75%t
镍铬-铜镍热电偶 E 0~600 2 ±2.5℃或 ±0.75%t
铂热电阻 Pt100 -200~500 B ±(0.3+0.005|t|)
注:t为感温元件实测温度或实测温度的值。
□公称压力
一般是指在常温下,保护管所能承受的静态外压而不破裂,试验压力一般采用公称压力的1.5倍。实际上,允许工作压力不仅与保护管材料、直径、壁厚有关,而且还与其结构形式、安装方法、置入深度以及被测介质的流速、种类有关。
□热电偶绝缘电阻
常温绝缘电阻的试验电压为直流500V。测量常温绝缘电阻的大气条件为:温度15~35℃,相对湿度45%RH,大气压力86~106kPa。
对于长度超过1米的热电偶,它的常温绝缘电阻值与其长度的乘积应不小于100MΩ•m,
即:Rr•L>100MΩ•mL>1m
式中:Rr-热电偶的常温绝缘电阻值,MΩ;
L-热电偶的长度,m。
对于长度等于或不足1米的热电偶,它的常温绝缘电阻值应不小于100MΩ。
□热电阻绝缘电阻
常温绝缘电阻的试验电压可取直流10~100V任意值,环境温度应在15~35℃范围内,相对湿度应不大于80%RH,常温绝缘电阻值应不小于100MΩ。
□热电阻允许通过电流
通过铂电阻的测量电流大不超过5mA。
石家庄市 太原市 呼和浩特市 唐山市 大同市 包头市 秦皇岛市 阳泉市 乌海市 邯郸市 长治市 赤峰市 邢台市 晋城市 通辽市 保定市 朔州市 鄂尔多斯市 张家口市 晋中市 呼伦贝尔市 承德市 运城市 巴彦淖尔市 沧州市 忻州市 乌兰察布市 廊坊市 临汾市 衡水市 吕梁市
沈阳市 长春市 哈尔滨市 大连市 吉林市 齐齐哈尔市 鞍山市 四平市 牡丹江市 抚顺市 辽源市 佳木斯市 本溪市 通化市 大庆市 丹东市 白山市 伊春市 锦州市 松原市 鸡西市 营口市 白城市 鹤岗市 阜新市 双鸭山市 辽阳市 七台河市 盘锦市 绥化市 铁岭市 黑河市 朝阳市 葫芦岛市
南京市 杭州市 合肥市 福州市 南昌市 济南市 无锡市 宁波市 芜湖市 厦门市 赣州市 青岛市 徐州市 温州市 蚌埠市 莆田市 宜春市 淄博市 常州市 嘉兴市 淮南市 三明市 吉安市 枣庄市 苏州市 湖州市 马鞍山市 泉州市 上饶市 东营市 南通市 绍兴市 淮北市 漳州市 抚州市 烟台市 连云港市 金华市 铜陵市 南平市 九江市 潍坊市 淮安市 衢州市 安庆市 龙岩市 景德镇市 济宁市 盐城市 舟山市 黄山市 宁德市 萍乡市 泰安市 扬州市 台州市 滁州市 新余市 |