电站测温用热电阻WZP2-421B 价格
产品概述
WZP2-421B电站测温用热电阻是一款专为电力行业设计的温度测量传感器,采用高精度铂电阻元件(Pt100分度号),适用于-200℃至600℃范围内的液体、蒸汽及气体介质温度监测。该产品采用不锈钢保护管,具有机械强度高、耐压性能优异的特点,能够适应电站高温高压环境的长期稳定工作。其装配式结构设计便于安装维护,零件通用性强,可快速更换易损件,降低使用成本。热响应时间短,能准确反映温度变化,配套显示仪表后可实现过程控制系统中的精确测温需求。4619
Technical Specifications
The WZP2-421B thermal resistor for power plant temperature measurement features a platinum resistance element (Pt100) with a measuring range of -200°C to 600°C. The stainless steel protective tube ensures durability in high-pressure environments, while the modular assembly design allows easy maintenance and part replacement. With rapid thermal response characteristics, it accurately tracks temperature fluctuations in fluids, steam, and gases. The product s standardized interface dimensions provide excellent compatibility with various display instruments and control systems. Its double-wound sensing element on an insulated frame delivers reliable average temperature detection in gradient environments.41326
结构特点
该产品采用全国统一设计标准,接线盒提供防溅或防水两种可选结构(420/421型为防溅式,430/431型为防水式),适应不同现场环境需求。感温元件通过细金属丝双绕在绝缘骨架上,确保测量稳定性;保护管可承受2.5MPa公称压力,最小插入深度为保护管外径的8-10倍。常温绝缘电阻不小于100MΩ(测试电压10-100VDC),在15-35℃环境下通过5mA电流时自热影响小于0.3℃,保证长期使用的精度可靠性。支持固定法兰安装方式,符合电站管道标准化连接要求。142124
Structural Advantages
Featuring a standardized configuration, the WZP2-421B offers optional splash-proof or waterproof junction boxes (420/421 series for splash-proof, 430/431 for waterproof). The sensing element consists of fine metal wires bifilar-wound on an insulated frame, while the protective tube withstands 2.5MPa nominal pressure with minimum insertion depth of 8-10 times the tube diameter. It maintains over 100MΩ insulation resistance at room temperature (test voltage 10-100VDC) and exhibits less than 0.3°C self-heating effect under 5mA current. The fixed flange mounting design facilitates secure pipeline integration in power plant applications.122226
应用场景
本产品广泛应用于火力发电机组中锅炉、汽轮机、蒸汽管道等关键部位的温度监控,可与温度变送器、调节器及记录仪表组成控制系统。在石油化工、冶金等领域同样适用,能够稳定测量固体表面及强振动环境下的介质温度。其法兰连接方式特别适合需要频繁检修的工况,多支式设计允许同步传输温度信号至多台显示设备,满足电站分布式监测需求。5827
Application Scenarios
Designed for critical temperature monitoring in boilers, turbines, and steam pipelines of thermal power units, this thermal resistor integrates seamlessly with transmitters and controllers to form process control systems. It performs reliably in petrochemical, metallurgical, and high-vibration environments for both fluid and surface temperature measurement. The flange mounting suits frequent maintenance scenarios, while multi-circuit versions enable simultaneous signal transmission to multiple displays for distributed monitoring in power plants.111618
电站测温用热电阻
WZC-130B,WZP-220B,WZP-221B,WZP-230B,WZP-231B,WZP2-220B,WZP2-221B,WZP2-230B,WZP2-231B,WZP-220AB,WZP2-220AB。WZC-220B,WZC-230B,WZC-220AB,WZP-320B,WZP-321B,WZP-330B,WZP-331B,WZP2-320B,WZP2-321B,WZP2-330B,WZP2-330B,WZC-320B,WZC-320B,WZP-420B,WZP-421B,WZP-430B,WZP-431B,WZP2-420B,WZP2-421B,WZP2-430B,WZP2-431B,WZP-42AB,WZP2-42AB,WZC-420B,WZC-430B,WZP-420B,WZP-421B,WZP-430B,WZP-430B,WZP-431B,WZP2-420B,WZP2-421B,WZP2-430B,WZP2-431B,WZP-42AB,WZP2-42AB,WZP-420B,WZC-430B,WZP-621B,WZP-621AB,WZP-631B,WZP2 -621B,WZP2 -621B,WZP2 -631B,WZP-621B,WZP-631B,WZP-621B,WZP2 -631B,WZP-621AB,WZP2-621AB,WZP-002,WZP-003,WZP-003A,WZCM-201,WZPM-201,WZPM-201,WZP-270S,WZP-26S,WZP-236SB,
量程规格
名 称 分度号 测温范围 ℃ 精度等级 允 差Δt
镍铬-镍硅热电偶 K 0~800 2 ±2.5℃或 ±0.75%t
镍铬-铜镍热电偶 E 0~600 2 ±2.5℃或 ±0.75%t
铂热电阻 Pt100 -200~500 B ±(0.3+0.005|t|)
注:t为感温元件实测温度或实测温度的值。
□公称压力
一般是指在常温下,保护管所能承受的静态外压而不破裂,试验压力一般采用公称压力的1.5倍。实际上,允许工作压力不仅与保护管材料、直径、壁厚有关,而且还与其结构形式、安装方法、置入深度以及被测介质的流速、种类有关。
□热电偶绝缘电阻
常温绝缘电阻的试验电压为直流500V。测量常温绝缘电阻的大气条件为:温度15~35℃,相对湿度45%RH,大气压力86~106kPa。
对于长度超过1米的热电偶,它的常温绝缘电阻值与其长度的乘积应不小于100MΩ•m,
即:Rr•L>100MΩ•mL>1m
式中:Rr-热电偶的常温绝缘电阻值,MΩ;
L-热电偶的长度,m。
对于长度等于或不足1米的热电偶,它的常温绝缘电阻值应不小于100MΩ。
□热电阻绝缘电阻
常温绝缘电阻的试验电压可取直流10~100V任意值,环境温度应在15~35℃范围内,相对湿度应不大于80%RH,常温绝缘电阻值应不小于100MΩ。
□热电阻允许通过电流
通过铂电阻的测量电流大不超过5mA。
第:北京、天津、沈阳、大连、哈尔滨、济南、青岛、南京、上海、杭州、武汉、广州、深圳、香港、澳门、重庆、成都、西安(18个)
第二级:石家庄、长春、呼和浩特、太原、郑州、合肥、无锡、苏州、宁波、福州、厦门、南昌、长沙、汕头、珠海、海口、三亚、南宁、贵阳、昆明、拉萨、兰州、西宁、银川、乌鲁木齐(25个)
第三级:唐山、秦皇岛、淄博、烟台、威海、徐州、连云港、南通、镇江、常州、嘉兴、金华、绍兴、台州、温州、泉州、东莞、惠州、佛山、中山、江门、湛江、北海、桂林(24个)
第四级:邯郸、鞍山、抚顺、吉林市、齐齐哈尔、大庆、包头、大同、洛阳、潍坊、芜湖、扬州、湖州、舟山、漳州、株洲、潮州、柳州(18个)
第五级:承德、保定、丹东、开封、安阳、泰安、日照、蚌埠、黄山、泰州、莆田、南平、九江、宜昌、襄樊、岳阳、肇庆、乐山、绵阳、丽江、延安、咸阳、宝鸡(23个)
|