电站测温用热电阻WZP2 -631B 厂家
产品概述
电站测温用热电阻WZP2-631B是一款专为电力行业设计的双支铂热电阻温度传感器,适用于发电机组及辅助设备的温度监测需求。该产品采用装配式结构设计,可直接测量-200℃至420℃范围内的液体、蒸汽、气体介质及固体表面温度。其核心感温元件由高精度铂丝绕组构成,具备优异的抗震性和长期稳定性,能与显示仪表、记录仪表及电子调节器配套使用,实现精准温度监控。产品符合电力行业应用场景的特殊要求,尤其适合30万/60万千瓦发电机组配套使用。2512
技术特点
WZP2-631B采用双支独立测温设计,可同时接入两套显示或控制系统,满足冗余测温需求。保护管选用不锈钢材质,通过特殊工艺加工确保机械强度和高耐压性能,适用于电站高温高压环境。产品配备防水式接线盒,防护等级高,能适应石油化工等复杂工况。热响应时间短,能快速捕捉温度变化,测温精度达到B级标准(允差±0.3℃或±0.005|t|)。独特的压簧式感温元件设计使产品具有抗振动、安装简便、维护便捷等优势。823
Product Introduction
The WZP2-631B thermal resistor is a dual-element platinum resistance thermometer specifically engineered for power plant temperature measurement applications. It supports simultaneous temperature monitoring through two independent Pt100 sensing elements, making it ideal for critical equipment monitoring in 300MW/600MW generator units. The sensor covers a broad measurement range from -200°C to 420°C with reliable performance in liquid, steam and gas media. Its robust stainless steel protection tube ensures durability under high-pressure conditions commonly found in boiler and turbine systems.2526
Technical Features
This thermal resistor features a spring-loaded sensing assembly that enhances vibration resistance and ensures firm contact with measured surfaces. The waterproof junction box design (IP65 equivalent) prevents moisture ingress in humid environments. With optimized thermal response characteristics, it delivers accurate real-time temperature data for process control systems. The modular construction allows easy replacement of components, reducing maintenance downtime. Product dimensions include standard insertion lengths of 250mm with Φ6mm probe diameter, suitable for most pipeline and equipment installation scenarios. Optional M33×2 threaded connections provide secure mounting in high-flow media applications.619
电站测温用热电阻
WZC-130B,WZP-220B,WZP-221B,WZP-230B,WZP-231B,WZP2-220B,WZP2-221B,WZP2-230B,WZP2-231B,WZP-220AB,WZP2-220AB。WZC-220B,WZC-230B,WZC-220AB,WZP-320B,WZP-321B,WZP-330B,WZP-331B,WZP2-320B,WZP2-321B,WZP2-330B,WZP2-330B,WZC-320B,WZC-320B,WZP-420B,WZP-421B,WZP-430B,WZP-431B,WZP2-420B,WZP2-421B,WZP2-430B,WZP2-431B,WZP-42AB,WZP2-42AB,WZC-420B,WZC-430B,WZP-420B,WZP-421B,WZP-430B,WZP-430B,WZP-431B,WZP2-420B,WZP2-421B,WZP2-430B,WZP2-431B,WZP-42AB,WZP2-42AB,WZP-420B,WZC-430B,WZP-621B,WZP-621AB,WZP-631B,WZP2 -621B,WZP2 -621B,WZP2 -631B,WZP-621B,WZP-631B,WZP-621B,WZP2 -631B,WZP-621AB,WZP2-621AB,WZP-002,WZP-003,WZP-003A,WZCM-201,WZPM-201,WZPM-201,WZP-270S,WZP-26S,WZP-236SB,
量程规格
名 称 分度号 测温范围 ℃ 精度等级 允 差Δt
镍铬-镍硅热电偶 K 0~800 2 ±2.5℃或 ±0.75%t
镍铬-铜镍热电偶 E 0~600 2 ±2.5℃或 ±0.75%t
铂热电阻 Pt100 -200~500 B ±(0.3+0.005|t|)
注:t为感温元件实测温度或实测温度的值。
□公称压力
一般是指在常温下,保护管所能承受的静态外压而不破裂,试验压力一般采用公称压力的1.5倍。实际上,允许工作压力不仅与保护管材料、直径、壁厚有关,而且还与其结构形式、安装方法、置入深度以及被测介质的流速、种类有关。
□热电偶绝缘电阻
常温绝缘电阻的试验电压为直流500V。测量常温绝缘电阻的大气条件为:温度15~35℃,相对湿度45%RH,大气压力86~106kPa。
对于长度超过1米的热电偶,它的常温绝缘电阻值与其长度的乘积应不小于100MΩ•m,
即:Rr•L>100MΩ•mL>1m
式中:Rr-热电偶的常温绝缘电阻值,MΩ;
L-热电偶的长度,m。
对于长度等于或不足1米的热电偶,它的常温绝缘电阻值应不小于100MΩ。
□热电阻绝缘电阻
常温绝缘电阻的试验电压可取直流10~100V任意值,环境温度应在15~35℃范围内,相对湿度应不大于80%RH,常温绝缘电阻值应不小于100MΩ。
□热电阻允许通过电流
通过铂电阻的测量电流大不超过5mA。
|